1. Product Introduction
HSSB202 live cable identification instrument, also known as cable identification instrument, multi-function cable identification instrument, intelligent cable identification instrument, is designed for power cable engineers and cable workers to solve the technical problems of cable identification. Users can accurately identify one of the target cables from multiple cables through the instrument to avoid serious accidents caused by mistaken sawing of live cables. Cable identification starts from the operation at both ends of the cable. The double numbering at both ends of the cable must be accurate. This instrument is designed with PSK technology combined with precise algorithms. No matter how reliable the memory of the on-site staff is, it cannot replace the identification of professional instruments. This product also has the functions of live cable identification, power-off cable identification, AC current testing, and AC voltage testing. It consists of a transmitter, a transmitting current clamp, a receiver, and a receiving flexible current clamp.
Transmitter: Transmits signals to the target cable during live cable identification and power-off cable identification. It has a built-in high-power rechargeable lithium battery, automatic impedance matching, and fully automatic protection. The transmitter adopts an integrated special tool box design, using polypropylene plastic as the raw material, adding a new type of composite filler for one-time injection molding, with low density, strength, rigidity, hardness, wear resistance, heat resistance, and insulation performance. The box can withstand a pressure of about 200kg, and the host's large LCD displays the remaining battery power in real time, with white backlight and dynamic indication of the transmission signal, which is clear at a glance.
Transmitter clamp: When identifying live cables, the transmitter clamp couples the signal emitted by the transmitter to the target cable. The jaw size is Φ120mm. The transmitter clamp is directional, and the transmission signal flows in from the direction indicated by the arrow on the transmitter clamp.
When identifying live cables: the clamp coupling output pulse current is used to transmit four frequencies: 625Hz, 1562Hz, 2500Hz, and 10kHz. It is coupled to the target cable through the transmitter clamp (the target cable is a three-core armored cable), and a composite pulse current signal is injected into the cable core. The pulse current generates an electromagnetic field around the target cable for the receiver and flexible current clamp to detect and identify; because the pulse current is directional, the detection is also directional.
When identifying power outages: direct output pulse current is used to inject pulse coded current signals into the cable core. The current generates an electromagnetic field around the target cable for the receiver and flexible current clamp to detect, decode, and identify. Because the current is directional, the detection is also directional.
Receiver: It is a handheld device with a 3.5-inch color LCD screen and a built-in high-speed microprocessor. Combined with precise algorithms, it can identify and decode the pulse coded current signal of the transmitter. It also has a signal strength calibration function to display the signal strength and test results, which is exquisite and intuitive. The color scale bar is dynamically displayed, which is clear at a glance. The cable identification is successful and the non-target cable is marked with ×. The target cable can be quickly and automatically identified. At the same time, the voltage range that can be tested is AC 0.00V~600V (50Hz/60Hz), the AC current range that can be measured is AC 0.00A~5000A (50Hz/60Hz), and the current frequency that can be measured is 45Hz~70Hz.
Flexible current clamp: It is a Roche coil with excellent transient tracking ability. It can quickly identify the pulse coded current generated by the transmitter and is suitable for thick cables or irregularly shaped conductors. The inner diameter of the clamp is about 200mm, and it can clamp cables below Φ200mm. It is not necessary to disconnect the measured line. Non-contact measurement is safe and fast.
Special note: This cable identification instrument has both live cable identification and power-off cable identification functions. When identifying power-off cables: it is strictly forbidden to connect to live cables. Live cable identification is only applicable to three-core armored cables. When identifying, the transmitting clamp and the receiving clamp cannot be mixed, and the direction of the input signal must be consistent.
2. Technical indicators
1. Reference conditions and working conditions
Impact | Baseline conditions | Working conditions | Remark |
Ambient temperature | 23℃±1℃ | -10℃~40℃ | / |
Environmental Wet | 40%~60% | <80% | / |
Measured voltage and current frequency | 50Hz±1Hz | 45Hz~70Hz | When testing voltage and current |
Receiver operating voltage | 7.4V±0.5V | 7.4V±1V | / |
Transmitter operating voltage | 11.1V±0.5V | 11.1V±1.5V | / |
External electric and magnetic fields | Avoid | ||
Cable location under test | The cable under test is located at the approximate geometric center of the flexible current clamp. |
2. Transmitter specifications
Function | Transmits composite pulse frequency current signal, displays remaining battery voltage, and dynamically indicates transmission status |
power supply | 11.1V large capacity rechargeable lithium battery, fully charged and can work continuously for about 8 hours |
Output method | Caliper coupling for power-on identification; direct output for power-off identification |
Transmitting frequency | 625Hz, 1562Hz, 2500Hz, 10KHz (when powered on), press the up and down arrow keys to adjust the transmission frequency |
Pulse voltage | 500V (power failure detection) |
Pulse current | Maximum 5A (depending on the size of the loop resistance) |
Pulse frequency | 1 time/second |
Pulse Width | 2ms |
Test line length | 3 meters, with alligator clips, 1 red and 1 black |
Launching clamp size | Length, width and thickness 320mm×180mm×35mm |
Inner diameter of firing clamp | φ125mm |
Transmitter cable length | 3m |
Ground pin size | Length, width and thickness: 225mm×100mm×10mm |
Transmitter size | 320mm×275mm×145mm |
Display Mode | Large LCD displays remaining battery voltage in real time, with backlight |
LCD Size | Length and width 128mm×75mm; display area 124mm×67mm |
Outer packaging size | Length, width and height: 400mm×245mm×335mm |
Operating temperature | -10℃~40℃ |
Storage conditions | -20℃~50℃, ≤95%RH, no condensation |
Backlight control | Yes, white backlight |
Operating temperature | -10℃~40℃ |
Storage conditions | -20℃~50℃, ≤95%RH, no condensation |
Instrument quality | Transmitter 2.5kg; Transmitter clamp 1.12kg; Total weight 4.44kg (including receiver) |
Battery level | When the battery voltage is lower than 9.65V, the low battery voltage icon is displayed to remind you to charge the battery; when it is lower than 9.5V, the device automatically shuts down. |
charger | 12.6V DC charger |
Charging port | Round charging port, DC logo |
Stress resistance | The transmitter adopts an integrated special tool box design, and the box can withstand a pressure of about 200kg. |
Pressure resistance | AC 3700V/rms (between the top and bottom of the instrument box) |
Electromagnetic properties | IEC61326(EMC) |
Reference safety regulations | IEC61010-1 (CAT Ⅲ 300V, CAT IV 150V, pollution degree 2) |
3. Receiver specifications
Function | Live cable identification, power-off cable identification; AC voltage, current, frequency measurement |
power supply | 7.4V large capacity rechargeable lithium battery, USB charging port, fully charged and can work continuously for about 6 hours |
Rated current | About 300mA max |
Display Mode | 3.5-inch true color LCD display, color icon indication |
Signal calibration | Yes, calibrate the transmit signal. The current percentage of the received signal to the transmit signal is between 75% and 135% of the calibrated value, which is one of the conditions for successful identification. |
After calibration, the test frequency and magnification cannot be changed, otherwise recalibration is required; recalibration is required for testing different cables | |
Direction recognition | Yes, the transmitting clamp, receiving clamp and loading signal must be in the same direction, which is one of the conditions for successful identification. |
Cable identification successful | Green check mark icon indicates (√) |
Non-target cable | Red and orange cross icon indication (×) |
Receiver size | Length, width and thickness: 207mm×101mm×45mm |
Flexible current clamp | About 630mm long, wire diameter 6 mm or 12.5mm |
Coil inner diameter | φ200mm (larger diameter can be customized as needed) |
Lead length | Flexible current clamp lead length: 2m |
Voltage test lead | 1m long (1 red and 1 black) |
Detection range | Power outage identification: The coil can detect pulse signals with a loop resistance of 0Ω to 10kΩ; when the loop resistance is 10kΩ, the transmitter battery must be above 11V (usually up to a cable length of 0-10 kilometers, mainly determined by the ground resistance and cable resistance) |
Live identification: The coil can detect pulse signals with a loop resistance of 0Ω to 200Ω; when the detection loop resistance is 200Ω, it is necessary to ensure that the transmitter battery power is above 11V (generally it can reach a cable length of 0-5 kilometers, mainly determined by the ground resistance and cable resistance) |
Yangzhou Husu Electric Power Technology Co., Ltd. is a high-tech enterprise integrating the research and development, production and sales of power testing equipment, instruments and meters, and power industry automation systems. At present, its products have been widely used in many fields such as electricity, water conservancy, petroleum, railways, chemicals, electronics, etc.